Minimum Concrete Retaining Wall Thickness

Concrete Retaining Walls How To Build Poured Walls The Concrete Network

Concrete Retaining Walls How To Build Poured Walls The Concrete Network

Https Www Alexandriava Gov Uploadedfiles Code Info Retaining 20wall 20details 20package 2011 10 Pdf

Https Www Alexandriava Gov Uploadedfiles Code Info Retaining 20wall 20details 20package 2011 10 Pdf

Foundation Wall Thickness Based On Walls Supported Upcodes

Foundation Wall Thickness Based On Walls Supported Upcodes

Selection Of Reinforced Concrete Retaining Wall Geometry

Selection Of Reinforced Concrete Retaining Wall Geometry

Chapter 4 Foundations California Residential Code 2016 Upcodes

Chapter 4 Foundations California Residential Code 2016 Upcodes

Concrete Retaining Walls Design Home Design Ideas

Concrete Retaining Walls Design Home Design Ideas

Concrete Retaining Walls Design Home Design Ideas

Thus it appears that in the example you provided the minimum wall thickness is 6 inches.

Minimum concrete retaining wall thickness.

Minimum thickness of walls 4 1 bearing walls. Enter the length feet. As soon as you go higher or have greater depths of soil pushing against the wall you need to increase the thickness to 10 inches. Top thickness 18 in.

These consists of a concrete or masonry wall of uniform thickness vertical wall reinforcing and transverse footing reinforcing are all designed for the lateral shear and cantilever bending movement plus the vertical weights of the wall footing and earth fills. Ubc specified minimum thickness of exterior basement wall and foundation wall to be 191mm. 1 2 3 4 5 6 6. Aci 530 1 05 section 3 3b nospecialinspectionisrequiredforretain ingwallsupto6feetinheight.

Enter the thickness inches. Retaining walls footings or any other volume of concrete. For more on designing bearing walls refer to chapter 11 of aci 318 19. B short retaining walls vertical walls up to about 3m in height are usually built as shown in figure 1 b.

V l x h x t. Poured concrete foundation walls that are less than 8 feet tall and have soil outside that is 6 or 7 feet deep against the wall can often be 8 inches thick and function quite well. In general poured concrete basement walls that are 8 feet tall or less and have no more than 7 feet of soil pressing against them from the outside function well at a thickness of 8 inches. Enter length and height in feet and thickness in inches.

Bottom retaining wall loads the following figure shows all the loads applied to the cantilever retaining wall where. Ubc recommends minimum thickness of bearing wall to 1 25 supported height or length whichever is shorter or not less than 102mm. Wall stem dimensions wall foundation dimensions width 1 ft strip width 1 ft strip height 13 5 ft length 9 75 ft thickness 8 in. When a taller wall or a higher level of soil or both come into play the thickness should increase to 10 inches.

Bed joints of the starting course over the concrete foundation may be between 1 4 and 3 4. Section 11 3 1 1 states that the minimum thickness shall be based on the shorter of either the unsupported wall height or length.

Building Guidelines Drawings Section B Concrete Construction

Building Guidelines Drawings Section B Concrete Construction

Chapter 4 Foundations 2010 Residential Code Of Ny Upcodes

Chapter 4 Foundations 2010 Residential Code Of Ny Upcodes

Https Www Fairfaxva Gov Home Showdocument Id 2831

Https Www Fairfaxva Gov Home Showdocument Id 2831

Http Www Seattle Gov Documents Departments Sdci Codes Seattleresidentialcode 2015srcchapter4 Pdf

Http Www Seattle Gov Documents Departments Sdci Codes Seattleresidentialcode 2015srcchapter4 Pdf

Source : pinterest.com